The Model 1304 Opacity Monitor Is a High Performance Opacity Monitoring System with Double-Pass Transmissometer. Meets or exceeds Revised PS-1 and ASTM D 6216-03 High Performance Opacity Monitoring System with Double-Pass Transmissometer does not have to mean complicated -The Model 1304 uses field proven and time tested optics and circuitry that is simple yet accurate. Each monitor and all its components are of the highest quality, pre-tested at the factory to your site specifications. The simple to follow instructions will have your monitor ready for service in hours after mechanical and electrical installation has been completed. We have taken the approach to design equipment with accuracy, maintenance and serviceability as the most important features. The 1304 Opacity monitor is designed with state of the art modular packaging and with serviceability in mind. A built-in TTL (through-the-lens) alignment system - The alignment target can be viewed through a window on the transceiver. Adjustments to changes in alignment are provided by a 3-point alignment system that is integral to the air plenum. This insures optimum reliability while enabling the system to be easily serviced and maintained in the field by plant service personnel. Service module with digital display – The service module is used to pass signals to and from the transceiver and control unit, display opacity via digital meter, initiate maintenance zero and span cycles and insertion of external current meter in the transceiver to control unit 4-20mA loop. The service module is very useful for trouble shooting or during EPA audits as the correlated opacity can be displayed on the DPM. This feature eliminates the necessity for a second person and sometimes-difficult communication between the control unit and the sensor locations. Swing Away Sensor - The swing away sensor makes cleaning the windows a breeze. Both sensors have alignment pins to assure no change in alignment after the sensors have been open and closed. Large heavy-duty latches make for an air and water tight seal. The sensors are attached to the air plenum by two drop on pivot pins. This makes for easy installation and should service ever be required easy removal, just swing open and lift off the pivot pins. Model 1304 Opacity Monitor comes with many standard features:
Specifications: Remote control unit: Numeric Digital Display 5/8 inch (15.9 mm), 4-digit LED Selectable for Instantaneous opacity, Average Opacity. Optional mg/m3 Display resolution 0.1% Opacity or 0.1 mg/m3 Alphanumeric 8 character LED (0.2") Fault Display Air purge low, No Stack Power, T2 4-20 Lost/low, Maintenance Mode, Window Dust, Zero Cal Fail, Span Cal Fail, Manual Cal. Operator Indicating LED’s Run, Alarm, Operate, Bargraph Left/Right: 51 segments LED (5.1”) for instant/average opacity. 20 segment LED (2.1”) for window dust and drift in % opacity High Opacity Set Point 0-100% of full scale or 0-4,000 mg/mg3 High Opacity Delay Adjustable 0-300 Seconds High Opacity Alarm Reset Automatic Open Transistor Collector Outputs Four selectable Dry Contacts Two selectable (option: two additional) Instantaneous Opacity and Average Outputs 4-20 mA grounded reference, 800 ohms max. (two additional optional) OPLR (Exit Correlation Lx / 2*Lt) 0.2 to 3.0 Enclosure NEMA 13, IP65, Height: 7.38" x Wide: 3.00: x Depth: 7.75", Weight: 6 lbs. Ambient Temperature Range +0° to +50°C ( +32° to + 122°F) Power Requirements 120 VAC (+/- 15%), 50/60 Hz, 22VA Network Protocol Modbus (ASCII or RTU mode), type RS-485, optically isolated, RS-232 with telephone modular handset connector. Configuration Speed 1200-38,400 baud, type RS-232 and RS-485 Transceiver Service module: Display 5/8 inch, 4-digit LED, selectable for % Opacity, % Transmittance Test jacks Transceiver to remote control current loop Diagnostics Loss of power, Current loop open, maintenance mode. Transceiver/ Reflector: Enclosure NEMA 4 watertight enclosure Path Length 2 to 15 feet, 0.6 to 4.6 meters. Longer available Optical System Light Source Aging Compensation Automatic Light Source Life > 5 years Ambient Temperature Limits -4° to +130°F (-20° to +54°C) (Cold weather option available.) Process Gas Up to 750°F (400°C), standard (higher available) Alignment Verification Passive Built-in through-the-lens system Mounting Flanges 3 inch IPS, 150# pipe flange Ambient Light Immunity Solid-state electronic light modulation Design and performance Meet or exceeds 40 CFR 60 appendix B, PS-1 and ASTM D 6216-03 Peak and Mean Spectral Response Photopic 515 to 585 nm, less than 10% of peak response outside 400 to 700 nm Relative spectral response <10% Angle of View < 4.0° from optical axis Angle of Projection < 4.0° from optical axis Calibration Error/accuracy +/- 1% of full scale Response time < 10 seconds Zero Drift < 0.5% Calibration Drift < 0.5% Operational Period In excess of PS-1 required 336 Hrs. Zero/Span Calibration Manual or automatic with zero mirror and neutral density filter Specifications subject to change without notice.
Opacity: Model 1304 Opacity Monitor |
|||||
|
KeikaVentures. Your compliance connection. · P.O. Box 4704 · Chapel Hill, NC · 27515 877.504.0956 (Toll Free) · 919.933.9569 (Voice) · 919.928.5173 (Fax) · Email Copyright © 2001-2007 Keika Ventures, LLC. All rights reserved. KeikaVentures is a small, woman-owned business registered in the CCR. Privacy Statement. Terms of Use & Disclaimer. |
|||||