Method 7400Asbestos and Other Fibers by PCMThis method is used for the determination of asbestos from workplace air samples. The sample is collected cellulose ester membrane filter (MCE) and analyzed using PCM (phase contrast light microscopy). Fibers < 0.25 µm diameter will not be detected by this method. This method is used primarily used for estimating asbestos concentrations since PCM does not differentiate between asbestos and other fibers. If identification of fibers is needed, NIOSH Method 7402 using electron microscopy can be used for confirmation. This method may be used for other materials such as fibrous glass by using alternate counting rules. The quantitative working range is 0.04 to 0.5 fiber/cc for a 1000-L air sample. The limit of detection (LOD) depends on sample volume and quantity of interfering dust, and is <0.01 fiber/cc for atmospheres free of interferences. NOTE: This revision replaces Method 7400, Revision #3 (date 5/15/89). (NIOSH Issue 2: 15 August 1994)
* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample. |
||||||||||||||||||||||||||
|
KeikaVentures. Your compliance connection. · P.O. Box 4704 · Chapel Hill, NC · 27515 877.504.0956 (Toll Free) · 919.933.9569 (Voice) · 919.928.5173 (Fax) · Email Copyright © 2001-2007 Keika Ventures, LLC. All rights reserved. KeikaVentures is a small, woman-owned business registered in the CCR. Privacy Statement. Terms of Use & Disclaimer. |
||||||||||||||||||||||||||